AquaLabo
AquaLabo DIGISENS
Part no.: PF-CAP-C-00160
DIGISENS is AquaLabo's range of digital sensors for dissolved oxygen, pH, ORP, conductivity, salinity and turbidity. Every sensor speaks Modbus RS-485 and keeps its own calibration.

France
Digital and optical water-quality sensors
AquaLabo manufactures water-quality meters and sensors, specialising in digital and optical measurement. The NEON handheld logs up to 3000 data points and transfers data over Wi-Fi; the DIGISENS sensor family, built in stainless steel or PVC, covers pH, ORP, temperature, conductivity, salinity, dissolved oxygen, turbidity and more.
AquaLabo
Part no.: PF-CAP-C-00160
DIGISENS is AquaLabo's range of digital sensors for dissolved oxygen, pH, ORP, conductivity, salinity and turbidity. Every sensor speaks Modbus RS-485 and keeps its own calibration.
AquaLabo
Part no.: NC-POR-C-00308
Handy oxygen meter for fish farming: NEON OPEN with a stainless steel OPTOD oxygen sensor on a 3 m cable, carrying case and sodium sulphite for calibration.
AquaLabo
Part no.: DIVNEG
Two-sensor probe with a C4E conductivity and salinity sensor and a titanium OPTOD oxygen sensor on a 30 m cable with a Fischer connector. Built for measurements at depth in sea cages.
AquaLabo
Part no.: PF-CAP-C-00168
Digital optical dissolved oxygen sensor in 316L stainless steel with a 7 m cable and bare wires. A robust sensor for most fish farming projects.
AquaLabo
Part no.: PF-CAP-C-00244
Digital optical dissolved oxygen sensor in titanium with a 7 m cable and bare wires. Titanium gives the best resistance to seawater and corrosion.
AquaLabo
Part no.: PF-CAP-C-00566
Digital optical dissolved oxygen sensor in titanium with a 30 m cable and bare wires. Titanium gives the best resistance to seawater and corrosion.
AquaLabo
Part no.: PF-CAP-C-00419
Digital optical oxygen sensor for fish farming, POM-C and PVC body with the standard strainer and a 7 m cable. The most cost-effective OPTOD version.
AquaLabo
Part no.: PF-CAP-C-00422
Digital optical oxygen sensor for fish farming with the longer, more protective strainer, on a 7 m cable.
AquaLabo
Part no.: PF-CAP-C-00169
Digital four-electrode sensor for conductivity, salinity and temperature, on a 3 m cable with bare wires.
AquaLabo
Part no.: PF-CAP-C-00573
Digital four-electrode sensor for conductivity, salinity and temperature, on a 30 m cable with bare wires.
AquaLabo
Part no.: PF-CAP-C-00171
Digital pH sensor with a 3 m cable and bare wires, supplied without cartridge. With a PHEHT cartridge it measures pH, ORP and temperature; with a pHT cartridge pH and temperature.
AquaLabo
Part no.: PF-CAP-C-00155
Replaceable cartridge for the PHEHT sensor, measuring pH, ORP and temperature.
AquaLabo
Part no.: PF-CAP-C-00616
Replaceable cartridge that turns the PHEHT sensor into a pHT sensor for pH and temperature.
AquaLabo
Part no.: ME-PCS-C-00317
Protective strainer that guards the cartridge of the PHEHT and pHT sensor.
AquaLabo
Part no.: PF-ACC-C-00478
Spare DODISK sensing disc for the OPTOD Plastic oxygen sensor, O-ring included.
AquaLabo
Part no.: PF-ACC-C-00479
Standard PVC strainer for the OPTOD Plastic oxygen sensor.
AquaLabo
Part no.: PF-ACC-C-00480
Longer PVC strainer that gives the OPTOD Plastic sensing disc more protection.
AquaLabo
Part no.: PF-ACC-C-00499
Copper antifouling protection for the OPTOD Plastic strainer that limits fouling and maintenance.
AquaLabo
Part no.: PF-CSO-C-00041
Strainer with integrated DODISK sensing disc for the stainless steel OPTOD oxygen sensor.
AquaLabo
Part no.: PF-CSO-C-00045
Strainer with integrated DODISK sensing disc for the titanium OPTOD oxygen sensor.
AquaLabo
Digital nephelometric turbidity sensor using 90° infrared scattering, from 5 to 4000 NTU.
AquaLabo
Digital ORP sensor with a platinum ring and temperature sensor, for example to follow ozone treatment in recirculating systems.
AquaLabo
Multiparameter probe for three DIGISENS sensors measuring up to 8 parameters at once, such as oxygen, pH, conductivity and turbidity.
AquaLabo
Part no.: PF-FIX-C-00085
Digital transmitter for two DIGISENS sensors with 4 to 20 mA outputs, relays, Modbus and Ethernet. A built-in barometric sensor compensates oxygen readings.
AquaLabo
Part no.: PF-FIX-C-00095
Multichannel digital transmitter for four DIGISENS sensors plus one third-party sensor, with a 7 inch touchscreen showing up to 12 parameters.
AquaLabo
Part no.: PF-ACC-C-00304
Regulated switch-mode AC-DC power supply that runs the ACTEON 6000 from 100 to 240 V mains.
AquaLabo
Part no.: PF-POR-C-00188
NEON OPEN handheld without sensor, with a connector for one DIGISENS sensor at a time: oxygen, pH, ORP, conductivity, salinity, turbidity and more.
AquaLabo
Part no.: NC-POR-C-00093
ODEON X handheld with two sensor inputs and Open technology, supplied as a set without probe.
AquaLabo
Part no.: NC-POR-C-00103
ODEON Open One handheld with one sensor input, supplied as a set without sensor.
AquaLabo
Part no.: NC-POR-C-00098
Oxygen meter set: ODEON Open One handheld with an OPTOD oxygen sensor on a 3 m cable with Fischer connector.
AquaLabo
Part no.: NC-ACC-C-00004
Charger cable with power supply and adapter for charging NiMH batteries inside the ODEON handheld.
AquaLabo
Part no.: PF-ACC-C-00190
Standard carrying case for the ODEON handheld and its sensors.